<https://lh3.googleusercontent.com/-hCi8VAOLk6w/WteFlSpO0sI/AAAAAAAAA44/Rv1usvxRrC0r96A7qPU6_nASMu_ZQMdfwCLcBGAs/s1600/20180417_113316.jpg>
I found the problem, clogged filter right past the solenoid switch, just 
past the braided input water line.  

On Wednesday, April 4, 2018 at 1:40:26 PM UTC-6, Carl Walker wrote:
>
> When I pull a shot it takes about 10 seconds for the machine to come up to 
> 9 bar.  this has just started in the last month and I have had the machine 
> for about two years.
>
> I have descaled, cleaned the group head, replaced the group head 
> gasket...all with no luck.  
>
> Any ideas?  I searched through old topics but didn't find this exact 
> question on the Rotary model.
>
> Thanks for any ideas.  
>

-- 