Thursday, April 26, 2018, 1:30:01 PM, you wrote:
| I have checked both high limits, they look fine. So I would really appreciate if someone could help me here. |
Did you push both high limits to see if they move?
What tools do you have at your disposal? Do you have a voltmeter?
If you measure across the elements in the boilers when it's sitting there, do you see 220V on either of them?
If you unplug the machine and measure the resistance of both elements, what do you get?
-- Ira --