I've had them fail both ways. I'd bet on the pressurestat. Herman
On Fri, Oct 18, 2019 at 1:40 AM Eric Christoffersen <[email protected]> wrote: > Brewtus 2 with pid and lots of other replaced parts. > > Heard hissing from machine and assumed it was a leaking vacuum breaker > valve. Replaced oring even though old looked good. > > Tonight i heard hissing again and luckily noticed the steam pressure was > pegged. Opened the tap and it took a lot of water and steam before pressure > dropped. > > The overpressure switch didnt fire, but i guess thats just if the pressure > valve doesnt leak. > > So... Whats the part i need? Is it the pstat? Last time mine died there > was no steam - i liked that failure mode better. > > Thanks! > Eric > > -- > You received this message because you are subscribed to the Google Groups > "Brewtus" group. > To unsubscribe from this group and stop receiving emails from it, send an > email to [email protected]. > To view this discussion on the web visit > https://groups.google.com/d/msgid/brewtus/5a463fc2-c6df-44a3-87d8-373704387f4a%40googlegroups.com > <https://groups.google.com/d/msgid/brewtus/5a463fc2-c6df-44a3-87d8-373704387f4a%40googlegroups.com?utm_medium=email&utm_source=footer> > . > -- You received this message because you are subscribed to the Google Groups "Brewtus" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To view this discussion on the web visit https://groups.google.com/d/msgid/brewtus/CAM9mha3v8UyG2enr6HRH_z5-5X%3DxJDf9OQX44tSxZCPJEgR6OQ%40mail.gmail.com.