https://sourceware.org/bugzilla/show_bug.cgi?id=34961

zhaozhou <zhaozhou at loongson dot cn> changed:

           What    |Removed                     |Added
----------------------------------------------------------------------------
                 CC|                            |zhaozhou at loongson dot cn

--- Comment #1 from zhaozhou <zhaozhou at loongson dot cn> ---
Hi,

I checked the reproduction and the current LoongArch backend.
With -mrelax, GAS emits each TLS-LE relocation followed by an R_LARCH_RELAX
marker. The reproduction reverses the LO12/RELAX pair; the sequence with the
not reverses relocation order relaxes is correct.

loongarch backend rely on this order convention in several places. I would
prefer to keep the existing convention: accepting reversed markers only for
TLS-LE would add a special case, and support alternative ordering throughout
the backend would require broader changes.

I would like to understand how this object file was generated. Could you share
the assembly source file?

-- 