On 03/12/2014 11:05 AM, Moritz Grimm wrote:
>> On a Shuttle DS47, with a recent Samsung SSD 840, significant I/O churn
>> (cvs checkout on top of existing repository, while removing another, and
>> some more) appears to have caused and/or triggered intermittent I/O errors.
>>
>> In dmesg, the error shows up as this:
>> ahci0: attempting to idle device
>> ahci0: couldn't recover NCQ error, failing all outstanding commands.
> [...]
>> sd0 at scsibus0 targ 0 lun 0: <ATA, Samsung SSD 840, DXM0> SCSI3
>> 0/direct fixed naa.5002538550409483
>> sd0: 122104MB, 512 bytes/sector, 250069680 sectors, thin
> 
> The exact model of this disk is MZ-7PD128 (SSD 840 Pro). Off-list, I was
> asked to check, if the disk runs the latest firmware.

A new firmware came out just around the time of that email, and I
upgraded (DXM06B0Q). No change in behaviour, and the NCQ/IO error is
very easy for me to reproduce on the Shuttle.

Next test I'll try is put the disk and the OpenBSD on it into an older
laptop. If I can't reproduce it there, I assume that it remains probable
that it is a Shuttle hardware and/or ahci driver issue. Otherwise, I
assume the issue to be tied to the disk itself.

Further testing ideas are very welcome.


Moritz