Marek Zelem wrote:
>       Hi all
>
>   Thanks a lot for your responses. I will change Fax passthru method of
> ATA to REINVITE (it was indeed NSE - thanks Damjan). I can experiment with
> it only out of working hours so I have to wait till evening.
>
>   But, I have a question about what Steve said. Does it have to be
> answering party who initiate switch to T38? I am pretty sure that when I
> am calling T38Gateway() it is fax on the line. At least nobody except the
> fax machine can answer the call. Is it possible to force somehow
> T38Gateway() to switch to T38. I found SipT38SwitchOver() but it does not
> work when call comes from CAPI and SIP is not involved yet.
>
>   And what about opposite direction? When fax machine is calling through
> ATA to Callweaver and ISDN. Will Callweaver detect fax and initiate switch
> to T.38? I just do T38Gateway() call to CAPI.
>   
The T.38 spec says the answering end of the T.38 link must initiate the 
T.38 negotiation. When we receive a call from a SIP device we listen for 
FAX tone from the destination FAX machine, and initiate T.38 negotiation 
when we hear the tone. When we start a SIP call we just wait for the far 
end to do something.