"Steve Wood" <[email protected]> wrote in 
message news:[email protected]...
>
> I have noticed there is a love-in on the SmartGauge range on this list
> at the moment (I REALLY hope someone is on commission ;D ) but given it
> monitors less information I fail to see how it can be more accurate in
> its guesses than the Victron, as has been suggested. Personally I'd
> rather have as much real information as possible and do my own guessing.

Could be a "love-in" because it works and for those with no technical 
knowledge it tells them the facts rather than having to work out an 
approximation.

Accuracy

Just take 2 examples

Battery when new 200Ah
discharge 100Ah to 50%
as battery gets old it looses capacity say to 180Ah
discharge 100Ah that you think is 50% but in reality its 55%
how will any shunted meter deal with that,  it just cant because you don't 
know how aged the batteries are, SG reads correctly.

My batteries have been off for a while, the shunted meter will still show 
100% but due to self discharge they have lost 7% SG shows 93%

This is without going into recharge / discharge cycles and the fact that you 
need to put in more than you take out to reach 100% which gets forgotten.


J 