Hello,
I'm in the middle of an upgrade to 4.2.x, however I have some problems with
the new encrypted flow keys in CAS.
I have some extensions to the webflow for which I want to use
redirect="true" on a view state in login-webflow:
<view-state id="askPasswordForSocialRegistrationView" view=
"askPasswordForSocialRegistrationView" model="social" redirect="true">
<transition to="checkPassword"/>
</view-state>
Now if I do that I get a redirect to a *very* long url. It differs a bit
(probably because the default is a compressed cipher), but it's in the
range of 6000 - 9000 characters. That is a bit long for a redirect (at
least Tomcat has a default maximum of 8096 characters (top of my head)
before it will bail out).
I really need the redirect, so what are my options? Can I lose the cipher?
Does it matter security-wise?
PS. Sorry if I double posted this to the old groups? I got a message saying
the other (Jasig) lists were decomissioned.
Auke
--
You received this message because you are subscribed to the Google Groups "CAS
Community" group.
To unsubscribe from this group and stop receiving emails from it, send an email
to [email protected].
Visit this group at https://groups.google.com/a/apereo.org/group/cas-user/.