Hi All.
The 10Ge and ADC blocks on ROACH now require no control software for
basic configuration.
The ADCs will 'automatically' set themselves into interleaved or normal
mode, while the 10Ge
will preconfigure its registers to the settings specified in the yellow
block.
This will allow the possibility of zero-config designs.
Regards,
David George
(note: the 10ge pre-configuration is also implemented on iBOB)
--
David George
Digital Design Engineer
Karoo Array Telescope
Tel: +27 21 531-7282
Fax: +27 21 531-9761
Email: [email protected]