Hi Wan, 

The labels below each of the Œstages¹ underneath your PFB block simply echo
the top level parameters of the block.  Each Œstage¹ is singular, your PFB
has a total of only 2 taps.

Regards, 

Andrew




On 6/17/09 11:37 PM, "[email protected]" <[email protected]> wrote:

> Please see the attached.
>  
> Thanks
>  
> Wan
> 
> 
> From: Andrew Siemion [mailto:[email protected]]
> Sent: Thursday, 18 June 2009 4:14 PM
> To: Cheng, Wan (ATNF, Marsfield); [email protected]
> Subject: Re: [casper] question on sync pulse
> 
> Hi Wan, 
> 
> What do you mean by a two-stage PFB?  Can you send around a copy of your model
> file?
> 
> - Andrew
> 
> 
> On 6/17/09 11:08 PM, "[email protected]" <[email protected]> wrote:
> 
>> Hi:
>> 
>> After  reading the memo of sync pulse, I still feel a little bit  confused.
>> 
>> I use a  PFB in my design. So I guess I have to include the order of PFB into
>> the  calculation.
>> 
>> The  order of PFB is 2. But there are two stage in the PFB. There are 2 taps
>> in the  second stage as well. So I set the reorder to 2 or 4?
>> 
>> For the  FFT, there are 2 order-2 reorder block in the bi_real_unscr_4x, so I
>> recorder  order should be 4.
>> Its FFT unscrambler use an 8 order block. So its order  is 8.
>> 
>> So the  sync period of FFT is 4*8*512/4 = 4096. Is this right?
>> 
>> What I  could not understand is the PFB. I use 2 order or 4?
>> 
>> Thanks
>> 
>> Wan
>> 
> 

Reply via email to