Hello

I use ISERDES to receive data over Black Box.
Simulation in Simulink is OK.
But while I generate the bof file over bee_xps, the error occurs!
The error message is as follows:
-----------------------------------------------------------------------------------------------------------
ERROR:PhysDesignRules:1242 - Invalid connection used for ISERDES. The ISERDES 
   comp 
   
roach_iserdes_6bit_XSG_core_config/roach_iserdes_6bit_XSG_core_config/roach_i 
   serdes_6bit_x0/iserdes_6bit/Iserdes_master D pin signal 
   roach_iserdes_6bit_gpio_gateway is not driven from an IO. 
ERROR:Pack:1642 - Errors in physical DRC. 
-----------------------------------------------------------------------------------------------------------

I also find some information about this error.
http://www.xilinx.com/support/answers/31620.htm

Should I fix the UCF file? or other idea?

Regards,
C-H Cheng

Reply via email to