Hi all. If your new ROACH boards have been exhibiting strange and random power-up behaviour you should be able to solve the problem. The Actel Fusion device is most probably not receiving an adequately long power-on reset pulse. Changing capacitor C33 from 0.01uF to 0.22uF (or 0.1uF) increases the pulse width and makes the part behave as it should.
You can test whether this is indeed the issue affecting your ROACH by pushing the chassis reset button. If the behaviour returns to normal, then you should change the cap. Regards, David -- David George Karoo Array Telescope Tel: +27 21 531-7282 Email: [email protected]