Hi all.

If your new ROACH boards have been exhibiting strange and random
power-up behaviour you should be able to solve the problem. The Actel
Fusion device is most probably not receiving an adequately long
power-on reset pulse. Changing capacitor C33 from 0.01uF to 0.22uF (or
0.1uF) increases the pulse width and makes the part behave as it
should.

You can test whether this is indeed the issue affecting your ROACH by
pushing the chassis reset button. If the behaviour returns to normal,
then you should change the cap.

Regards,
David


-- 
David George
Karoo Array Telescope
Tel: +27 21 531-7282
Email: [email protected]