hi dale, if you have an old iBOB, it might be a shorted PCB trace under the xaui/ethernet connector. check out memo 24, at: http://casper.berkeley.edu/wiki/Memos dan On 12/09/2010 08:50 AM, Gary, Dale wrote:
Hi All, We have been running four IBOBs as a spectrometer for about a year, and one of the IBOBs is no longer taking telnet connections via ETH0. I checked the voltages, and all are present. I reprogrammed the FPGA, and that was successful (as reported by Impact), but there was no change. Is there anything else I could do to test/debug it, or should I just send it back to Digicom? Thanks, Dale
-- Dan Werthimer Space Sciences Lab and Berkeley Wireless Research Center University of Calfornia, Berkeley