> After working on the 10Gbe for a while and reading the replies to this
> thread
> http://www.mail-archive.com/[email protected]/msg02275.html, we
> used a reset scheme that holds the valid into 10Gbe low first, and then
> reset the 10Gbe, then let it startup, and release the valid line last
> and start transmitting data.
>
> However, there seems to be an inserted word in the beginning when the
> 10Gbe starts to transmit. It is always the first word of the first
> packet, and it happens randomly. Sometimes it's find and sometimes it's
> not, we have to keep doing reset and if lucky enough we will get it
> right. Is this a known issue to 10Gbe or has anyone found a good work
> around?
>

The reset line is flaky.  Don't use it...

:(

John



Reply via email to