Hi, Joe, Please see this message:
http://www.mail-archive.com/[email protected]/msg04430.html Dave On Sep 20, 2013, at 2:06 PM, Kujawski, Joseph wrote: > I am receiving an error in trying to generate a simple design that feeds the > ADC to a comparator bank which illuminates the ROACH2 front panel LEDs based > on the voltage level of thee received signal. The error message is as > follows: > > **************************************************************************** > > ############################# > ## Block objects creation ## > ############################# > Problem with block: adc_test/adc16x250-8 > : The Gateway block xps_library_ADCs_adc16x250_8_a1 does not respect the > hierachical naming convention (it should start with adc_test_adc16x250_8). > Backtrace 1: xps_block:82 > Backtrace 2: gen_xps_files:236 > Backtrace 3: run_Callback:153 > Backtrace 4: casper_xps:86 > Backtrace 5: > @(hObject,eventdata)casper_xps('run_Callback',hObject,eventdata,guidata(hObject)):0 > Error using gen_xps_files (line 260) > Error found during Object creation. > > **************************************************************************** > > This problem occurs when only 'Update System' is checked in the casper_xps > program. > > Does anyone know how to fix this problem? > > -Joe Kujawski > > -- > ************************************** > * Joe Kujawski > * Siena College > * Dept. of Physics and Astronomy, RB 113 > * 515 Loudon Road > * Loudonville, NY 12211-1462 > * > * Email: [email protected] > * Phone: 518-782-6885 > * Fax: 518-783-2986 > ************************************** >