Hi, Joe,

Please see this message:

http://www.mail-archive.com/[email protected]/msg04430.html

Dave

On Sep 20, 2013, at 2:06 PM, Kujawski, Joseph wrote:

> I am receiving an error in trying to generate a simple design that feeds the 
> ADC to a comparator bank which illuminates the ROACH2 front panel LEDs based 
> on the voltage level of thee received signal.  The error message is as 
> follows:
> 
> ****************************************************************************
> 
> #############################
> ## Block objects creation  ##
> #############################
> Problem with block: adc_test/adc16x250-8
> : The Gateway block xps_library_ADCs_adc16x250_8_a1 does not respect the 
> hierachical naming convention (it should start with adc_test_adc16x250_8).
> Backtrace 1: xps_block:82
> Backtrace 2: gen_xps_files:236
> Backtrace 3: run_Callback:153
> Backtrace 4: casper_xps:86
> Backtrace 5: 
> @(hObject,eventdata)casper_xps('run_Callback',hObject,eventdata,guidata(hObject)):0
> Error using gen_xps_files (line 260)
> Error found during Object creation.
> 
> ****************************************************************************
> 
> This problem occurs when only 'Update System' is checked in the casper_xps 
> program.
> 
> Does anyone know how to fix this problem?
> 
> -Joe Kujawski
> 
> -- 
> **************************************
> * Joe Kujawski
> * Siena College
> * Dept. of Physics and Astronomy, RB 113
> * 515 Loudon Road
> * Loudonville, NY 12211-1462
> *
> * Email: [email protected]
> * Phone: 518-782-6885
> * Fax: 518-783-2986
> **************************************
> 


Reply via email to