Hi Richard, The Roach2 enclosure changes I know about may be found at https://casper.berkeley.edu/wiki/ROACH_2_Enclosure
I work with at least 4 different versions of the Roach2 enclosure. Each customized by us (the end-user) or by special arrangement with Digicom. Maybe others know of tricky mounting schemes that require no drilling/filing/... ? Matt On Thu, 6 Mar 2014, Richard Black wrote:
Date: Thu, 6 Mar 2014 14:21:40 -0700 From: Richard Black <[email protected]> To: casper <[email protected]> Subject: [casper] Mounting ADCs in ROACH-2 Enclosures Hi all, I was just attempting to connect the 64ADCx64-12 into a ROACH-2 enclosure. I took off the front-panel that came with the ROACH-2 board to find a completely forged enclosure with the same holes drilled out as in the out-of-the-box front panel. At first glance, this makes the idea of mounting an ADC impossible without further drilling. We also have some ADC16x250-8 RJ45 cards with compatible front panels. With the current ROACH-2 enclosure, I do not see any way of fitting these ADCs into the enclosure either without drilling more holes. Was the expectation for the user to drill new holes into the ROACH-2 enclosure, or is there some way of mounting these ADCs that I'm missing. Thanks, Richard Black