Hi Carspers,
I have installed again the toolflow for the ROACH-1 in a new
workstation with 16 cores and 192GB of RAM memory. I did my first
compile test with a big project and the XST generation took more than
5 hours (rather than 1 on the old machine!) while the ISE/EDK stuff
took only 40 minutes.
I have read some Xilinx issue about permission of the cache
directories. I will make other tests on Monday, it seems that the
cached files have been generated on the right places, after reading to
this mail I WILL DEFINITELY check the Matlab Java Heap !!!!!

Thanks a lot!!!!!

Cheers,
Andrea

2014-04-12 20:24 GMT+02:00 Matt Strader <[email protected]>:
> Thanks, Glenn.  Increasing the matlab java heap did the trick.    And
> thanks, Ryan, for your tip.  I may have to do that next.
>
> Matt
>
>
> On Fri, Apr 11, 2014 at 6:46 PM, Ryan Monroe <[email protected]>
> wrote:
>>
>> If you're filling a roach 2, you'll have to use the black box trick (on a
>> phone so I can't find it).  split the design into 2-4 equal parts on terms
>> of resources used!
>>
>> On Apr 11, 2014 6:34 PM, "G Jones" <[email protected]> wrote:
>>>
>>> Did you increase your matlab java heap? Search the mailing list archives,
>>> sounds like it could be the culprit.
>>>
>>> Glenn
>>>
>>> On Apr 11, 2014 9:31 PM, "Matt Strader" <[email protected]>
>>> wrote:
>>>>
>>>> Hi all,
>>>>
>>>> I have a rather large design I'm trying to compile for Roach2.
>>>> Compilation never gets past xst in System Generator, but doesn't give any
>>>> error.  Progress seems to halt while trimming pins, stopping in the middle
>>>> of printing a warning, such as
>>>> "WARNING:Xst:1710 - FF/Latch <fft_stage_6_".
>>>> Then cpu usage drops to near zero, and it just hangs there.  It never
>>>> takes more than 16% of my RAM, so it's not lagging from lack of memory.
>>>>
>>>> If I cut a big chunk out of my design, it compiles successfully.
>>>>
>>>> Any suggestions?
>>>>
>>>> Thanks,
>>>> Matt Strader
>>>> UCSB Physics Dept.
>
>



-- 
Andrea Mattana

I.N.A.F. - Istituto di Radioastronomia
Radiotelescopi di Medicina
Via Fiorentina, 3513 - 40059 Medicina (Bo)
Tel. 051/6965834      Fax. 051/6965810

Reply via email to