Several of the MKID systems use I/Q inputs. There's no real trick, they
just go through PFB_FIR real blocks (one for each I and Q) and then into
the classic fft block as the real and imag parts of the input data.

On Fri, Nov 7, 2014 at 1:57 PM, John Ford <[email protected]> wrote:

> Hi all.  Are there any example spectrometers or correlators that use I/Q
> sampling as opposed to the usual real-valued ADCs we generally use
> nowadays?  It seems like some early designs used these.
>
> We need to build a design that uses an I/Q stream as input, and we'd like
> to get a jump start on it by starting with a working model.
>
> Thanks!
>
> John
>
>
>
>

Reply via email to