Hi, Laura, On Nov 19, 2014, at 9:04 AM, Vertatschitsch, Laura E. wrote:
> I'm using the sma-wideband fork of mlib_devel, and I am at commit 263df71 > from Sep 24 this year. > > Rurik checked in a design he made with a software register, and when I > attempt to edit it and double click to view the options, I get a popup error: > -->Error evaluating 'MaskCallback' callback of swreg block (mask) 'r2dbe_top > /r2dbe/quantize_0/thresh'. -->Not enough input arguments. -->Error evaluating > 'MaskCallback' callback of swreg block (mask) 'r2dbe_top > /r2dbe/quantize_0/thresh'. -->Undefined function 'swreg_maskcheck' for input > arguments of type 'char'. -->Error evaluating 'MaskCallback' callback of > swreg block (mask) 'r2dbe_top /r2dbe/quantize_0/thresh'. -->Undefined > function 'swreg_maskcheck' for input arguments of type 'char'. -->Error > evaluating 'MaskCallback' callback of swreg block (mask) 'r2dbe_top > /r2dbe/quantize_0/thresh'. -->Undefined function 'swreg_maskcheck' for input > arguments of type 'char'. > > Ignoring the obvious names of variables in our particular design, seems there > are callback issues with swreg_maskcheck. After closing the popup, I get to > the options dialog: > Mode: one value This "Mode: one value" does not appear in the mask of the software register block in mlib_devel commit 263df71 (or in any of its ancestral commits). Either Rurik was using a different mlib_devel version or he copied this yellow block from a model that was built using a different mlib_devel version (or some other nefarious misdeeds occurred). I think the fix Jack described should resolve this: On Nov 7, 2014, at 3:03 AM, Jack Hickish wrote: > For sanity, you can do this automatically from the matlab prompt with the > command (open your model first so bdroot points to it): > > >> update_casper_blocks(bdroot, 'Tag', 'xps:sw_reg') > > You can update *all* casper blocks with: > >> update_casper_blocks(bdroot) ...but it might fail if you don't have the fixed-point toolbox because the swreg_init.m script seems to require the 'simulink/Commonly Used Blocks/Data Type Conversion' block which I think is part of the fixed-point toolbox. I think this might be required even if the register only has one value. It would be great to eliminate this dependency on the fixed-point toolbox. HTH, Dave