Hi, Charles, Is it when you click OK on a block's mask dialog or when you run "update diagram" or ???
Maybe you can find additional details in the "<model>_sysgen.log" or "<model>_sysgen_warning.log" or "<model>_sysgen_error.log" files? It would really help to know which block or file is causing this error. Thanks, Dave On Mar 9, 2015, at 6:24 AM, Charles Copley wrote: > Hi all, > > I have a strange error that arises after a small change to a design: > > I have used the sync pulse to reset a counter, that in turn (together with a > comparator coupled to a register) produces a higher frequency pulse for use > in snap blocks i.e. to write the snap block data more frequently than simply > using the sync pulse for synchronizing the data to the FFT windows. > > As soon as I do this I get the error in the subject line: > "Operands to the || and && operators must be convertible to logical scalar > values" > > This does not happen if I use the sync pulse directly, without the counter. > > All the data types are identical after a port update. > > Does anyone have this problem with the 2014 July Casper toolflow? > > Thanks in advance... > > > Charles Copley > > Cell: +27 (0) 84 430 1160 > --------------------------------------------------------------------------- >