Hi Michael, I just cloned https://github.com/casper-astro/tutorials_devel.git and compiled tut3_noquant_r111 against mlib_devel b6e70b660910482b1f1028d32d29284468e38cda using Xilinx 14.7 and MATLAB 2012b (I ran update_casper_blocks(bdroot) on the model, and changed the target for roach2 before compiling).
The resulting boffile outputs reasonable looking spectra when snapped with tut3_noquant_r111.py from the tutorials_devel repository (with default options, specifying only the boffile and roach2 host). I printed the first 20 channels and there are no zeros. Jack On Tue, 5 Jan 2016 at 05:21 Michael D'Cruze < [email protected]> wrote: > Dear all, > > > > First of all a happy new year to everyone! > > > > I continue to chase the problem I’ve been having for some time now, i.e. > spectrometer designs accumulating using 64-bit vacc blocks output zeroes > for every other channel. This happens with the tut3_noquant tutorial design > as well which is worrying. I’ve tried compiling the raw tut3_noquant design > on three separate machines using all perturbations of the 14.x ISE > versions, MATLAB 2012b and 2013a, as well as a few different versions of > the CASPER libraries. I have also run the design on both a ROACH-1 and a > ROACH-2. I believe this eliminates most random possibilities… > > > > I am hoping, if you have some time, that a few of you could try to verify > what I’m seeing. This should just involve compiling the tut3_noquant > design, running it, then pulling off a spectrum. > > > > Many thanks in advance > > Michael >