Hi Michael,

I just cloned https://github.com/casper-astro/tutorials_devel.git and
compiled tut3_noquant_r111 against mlib_devel
b6e70b660910482b1f1028d32d29284468e38cda using Xilinx 14.7 and MATLAB 2012b
(I ran update_casper_blocks(bdroot) on the model, and changed the target
for roach2 before compiling).

The resulting boffile outputs reasonable looking spectra when snapped
with tut3_noquant_r111.py from the tutorials_devel repository (with default
options, specifying only the boffile and roach2 host). I printed the first
20 channels and there are no zeros.

Jack





On Tue, 5 Jan 2016 at 05:21 Michael D'Cruze <
[email protected]> wrote:

> Dear all,
>
>
>
> First of all a happy new year to everyone!
>
>
>
> I continue to chase the problem I’ve been having for some time now, i.e.
> spectrometer designs accumulating using 64-bit vacc blocks output zeroes
> for every other channel. This happens with the tut3_noquant tutorial design
> as well which is worrying. I’ve tried compiling the raw tut3_noquant design
> on three separate machines using all perturbations of the 14.x ISE
> versions, MATLAB 2012b and 2013a, as well as a few different versions of
> the CASPER libraries. I have also run the design on both a ROACH-1 and a
> ROACH-2. I believe this eliminates most random possibilities…
>
>
>
> I am hoping, if you have some time, that a few of you could try to verify
> what I’m seeing. This should just involve compiling the tut3_noquant
> design, running it, then pulling off a spectrum.
>
>
>
> Many thanks in advance
>
> Michael
>

Reply via email to