Hi Jack,

I did try all the combinations. The error remains the same.

$ adc16_init.rb -v --demux=1 192.168.10.5 poly_design.bof

/var/lib/gems/1.9.1/gems/adc16-0.3.6/bin/adc16_init.rb:40:in `<top
(required)>': invalid option: --demux=2 (OptionParser::InvalidOption)

from /usr/local/bin/adc16_init.rb:19:in `load'

from /usr/local/bin/adc16_init.rb:19:in `<main>'


Sincerely,


*Vishwa Seneviratne*

*Graduate Student*

*Dept. of Electrical and Computer Engineering*
*University of Akron*

On Wed, Feb 3, 2016 at 2:25 AM, Jack Hickish <jackhick...@gmail.com> wrote:

> Hi Vishwa,
>
> Is the syntax definitely -demux=1 andnot either --demux=1 or -d 1 ?
>
>
> Jack
>
> On Wed, 3 Feb 2016, 12:39 a.m. Vishwa Seneviratne <mp...@zips.uakron.edu>
> wrote:
>
>> Hi,
>>
>> I am working on how to work with different operating of the 'ADC16x250-8
>> coax rev 2' for a very simple design to test how the ADC works. The design
>> is compiled at an IP clock rate setting of 200MHz. My objective is to
>> sample my input signal at higher sampling rate (preferably 400, 800 MHz).
>>
>> According to the user guide ''
>> https://casper.berkeley.edu/wiki/images/4/4c/ADC16_user_guide.txt"; by
>> setting the demux parameter I should be able to switch between different
>> sampling rates. I get the following error.
>>
>> $ adc16_init.rb -v -demux=1 192.168.10.5 poly_design.bof
>>
>> /var/lib/gems/1.9.1/gems/adc16-0.3.6/bin/adc16_init.rb:40:in `<top
>> (required)>': invalid option: -demux=2 (OptionParser::InvalidOption)
>>
>> from /usr/local/bin/adc16_init.rb:19:in `load'
>>
>> from /usr/local/bin/adc16_init.rb:19:in `<main>'
>>
>> When I don't pass the 'demux' parameter the ADC board get initialized to
>> 8 analog inputs by default.
>>
>> How do I resolve this issue? or how can I set the ADC's to operate at
>> different sampling rates?
>>
>> Thank you in advance
>>
>> Sincerely,
>>
>>
>> *Vishwa Seneviratne*
>>
>> *Graduate Student*
>>
>> *Dept. of Electrical and Computer Engineering*
>> *University of Akron*
>>
>

Reply via email to