Yes I can ping the interfaces and I have failover link configured.If I do the failover active that works.
Regards Imran On Sat, Oct 17, 2009 at 1:22 AM, Dave Craddock <[email protected]> wrote: > Can you ping the active and standby addresses on both sides of the > firewalls > > And how have you got your failover link configured and connected? > > > > Dave > > > > > > From: [email protected] > [mailto:[email protected]] On Behalf Of OSL CCIE > Security Lab Exam > Sent: 16 October 2009 20:03 > To: Cisco certification; [email protected] > Subject: [OSL | CCIE_Security] Active/standby failover on Qemu issues > > > > Hi All, > > > The issue is iam doing active standby.I have got sw1 connected on > outside and sw2 inside.To the switch are connected the routers. > > Iam able to ping the routers ie the traffic is going through the > firewall primary.But iam not able to replicate the failover. > > Suppose if i enable monitor interface on inside and shut down the link > on the sw2 where it is connected to inside interface i cannot see the > failover happening. > when i do show monitor interface everything shows normal.even if i > remove the link.So how should i create the failover scenario. > > I > Regards > Imran > >
_______________________________________________ For more information regarding industry leading CCIE Lab training, please visit www.ipexpert.com