Hi, Here is my config
interface Ethernet0/0 nameif outside security-level 0 ip address 10.1.1.2 255.255.255.0 standby 10.1.1.3 ! interface Ethernet0/1 nameif inside security-level 100 ip address 20.1.1.2 255.255.255.0 standby 20.1.1.3 ! interface Ethernet0/2 description LAN/STATE Failover Interface ! interface Ethernet3 shutdown no nameif no security-level no ip address ! interface Ethernet4 shutdown no nameif no security-level no ip address ! ftp mode passive pager lines 24 mtu outside 1500 mtu inside 1500 failover failover lan unit primary failover lan interface FAIL Ethernet0/2 failover link FAIL Ethernet0/2 failover interface ip FAIL 40.1.1.2 255.255.255.0 standby 40.1.1.3 icmp unreachable rate-limit 1 burst-size 1 no asdm history enable arp timeout 14400 ****************************************************************************** failover failover lan unit secondary failover lan interface FAIL Ethernet0/2 failover link FAIL Ethernet0/2 failover interface ip FAIL 40.1.1.2 255.255.255.0 standby 40.1.1.3 Please help me with. Is ur active/standby working Qemu ?? Regards Imran On Sat, Oct 17, 2009 at 9:59 AM, Johan Bornman <[email protected]> wrote: > Send your configs please. > > > > *From:* [email protected] [mailto: > [email protected]] *On Behalf Of *imran mohammed > *Sent:* 17 October 2009 06:27 > *To:* Dave Craddock > *Cc:* Cisco certification; OSL CCIE Security Lab Exam > *Subject:* Re: [OSL | CCIE_Security] Active/standby failover on Qemu > issues > > > > Yes I can ping the interfaces and I have failover link configured.If I do > the failover active that works. > > Regards > Imran > > On Sat, Oct 17, 2009 at 1:22 AM, Dave Craddock <[email protected]> wrote: > > Can you ping the active and standby addresses on both sides of the > firewalls > > And how have you got your failover link configured and connected? > > > > Dave > > > > > > From: [email protected] > [mailto:[email protected]] On Behalf Of OSL CCIE > Security Lab Exam > Sent: 16 October 2009 20:03 > To: Cisco certification; [email protected] > Subject: [OSL | CCIE_Security] Active/standby failover on Qemu issues > > > > > Hi All, > > > The issue is iam doing active standby.I have got sw1 connected on > outside and sw2 inside.To the switch are connected the routers. > > Iam able to ping the routers ie the traffic is going through the > firewall primary.But iam not able to replicate the failover. > > Suppose if i enable monitor interface on inside and shut down the link > on the sw2 where it is connected to inside interface i cannot see the > failover happening. > when i do show monitor interface everything shows normal.even if i > remove the link.So how should i create the failover scenario. > > I > Regards > Imran > > >
_______________________________________________ For more information regarding industry leading CCIE Lab training, please visit www.ipexpert.com