Is this right? It only works for telnet. After i entered rotary 15 and 
reenabled telnet I could telnet to port 3015. But if I ssh it fails to open a 
connection on same port.
 
So rotary on a switch only works for telnet or is this specific to 3750G or am 
I missing something here?
 

Thanks and regards

Yogesh Gawankar


--- On Thu, 8/5/10, Kingsley Charles <[email protected]> wrote:


From: Kingsley Charles <[email protected]>
Subject: Re: [OSL | CCIE_Security] Rotary on vty line
To: "Yogesh Gawankar" <[email protected]>
Cc: [email protected]
Date: Thursday, August 5, 2010, 3:54 PM


The port number can be 3018, 5018 or 7018









Table 1 Services and Port Numbers for Rotary Groups and Lines 



Services Provided 

Base TCP Port for Rotaries 

Base TCP Port for 
Individual Lines 


Telnet protocol 

3000 

2000 


Raw TCP protocol (no
Telnet protocol) 

5000 

4000 


Telnet protocol, binary mode 

7000 

6000 


XRemote protocol 

10000 

9000 


With regards
Kings


On Thu, Aug 5, 2010 at 8:48 AM, Yogesh Gawankar <[email protected]> wrote:






HI all
 
I have put in rotary 18 under vty 0 on a 3750G-24 port switch. However I am 
unable to connect to it.Does anyone know what the port number would be ? Also 
don't the switches support ip ssh port command like the routers?


Thanks and regards

Yogesh Gawankar

_______________________________________________
For more information regarding industry leading CCIE Lab training, please visit 
www.ipexpert.com





      
_______________________________________________
For more information regarding industry leading CCIE Lab training, please visit 
www.ipexpert.com

Reply via email to