Is this right? It only works for telnet. After i entered rotary 15 and reenabled telnet I could telnet to port 3015. But if I ssh it fails to open a connection on same port. So rotary on a switch only works for telnet or is this specific to 3750G or am I missing something here?
Thanks and regards Yogesh Gawankar --- On Thu, 8/5/10, Kingsley Charles <[email protected]> wrote: From: Kingsley Charles <[email protected]> Subject: Re: [OSL | CCIE_Security] Rotary on vty line To: "Yogesh Gawankar" <[email protected]> Cc: [email protected] Date: Thursday, August 5, 2010, 3:54 PM The port number can be 3018, 5018 or 7018 Table 1 Services and Port Numbers for Rotary Groups and Lines Services Provided Base TCP Port for Rotaries Base TCP Port for Individual Lines Telnet protocol 3000 2000 Raw TCP protocol (no Telnet protocol) 5000 4000 Telnet protocol, binary mode 7000 6000 XRemote protocol 10000 9000 With regards Kings On Thu, Aug 5, 2010 at 8:48 AM, Yogesh Gawankar <[email protected]> wrote: HI all I have put in rotary 18 under vty 0 on a 3750G-24 port switch. However I am unable to connect to it.Does anyone know what the port number would be ? Also don't the switches support ip ssh port command like the routers? Thanks and regards Yogesh Gawankar _______________________________________________ For more information regarding industry leading CCIE Lab training, please visit www.ipexpert.com