Dear Jason, Shingei, I am installing 7.0 CUCM om MCS servers. I did reset the passowrd and reload the pub after applying license.
Do you have any good doc. for troubleshooting this issue ? Regards, Wael Agina On Fri, Nov 26, 2010 at 8:17 AM, Jason Aarons (US) < [email protected]> wrote: > I had this problem with a recent new install of 8.0.2c (it was > pre-installed on the hard drive on new MCS server) . I couldn’t find > anything wrong, the password I reset 20 times, etc. > > > > I upgraded the pub to 8.0.3a and did a subscriber install with software > update on the subscriber and it worked fine. > > > > *From:* [email protected] [mailto: > [email protected]] *On Behalf Of *Wael Agina > *Sent:* Thursday, November 25, 2010 5:29 PM > *To:* Michael Dietrich > *Cc:* OSL Group > *Subject:* Re: [OSL | CCIE_Voice] Adding subscriber problem - need ideas > > > > Dearl Michael > > First i have applied license for two nodes and only using one and there > is one available node on the lices [for sub] > Also I set the name with uppercase all lettters and tried on sub both upper > case and lower case but not working. > I did reset security password many times to cisco12345 on pub and used it > on sub but no sccess. > > Is there any troubleshooting steps can be done on pub during connectivity > test on sub ? > > Regards, > Wael Agina > > On Fri, Nov 26, 2010 at 1:23 AM, Michael Dietrich <[email protected]> > wrote: > > Make sure that you are entering the device name of the PUB correctly > (spelling) during the SUB set up > > > > Make sure the server name for SUB is spelled correctly on the PUB (case > sensitive)...AND..... that you have a second server license installed on the > PUB, to be used by the SUB > > > > > > On Thu, Nov 25, 2010 at 3:13 PM, Wael Agina <[email protected]> wrote: > > Hi Prashant , > > Yes I added it on the publisher on server list and on the CM Group. > But still it fails the connectivity test when installing subscriber > software. > > Regards, > Wael Agina > > > > On Fri, Nov 26, 2010 at 12:31 AM, Prashant Patel < > [email protected]> wrote: > > Hi, > > > > Hope you have added the Sub in the list of servers on the Publisher. > > > > HTH > > Prashant > > On Thu, Nov 25, 2010 at 4:25 PM, Wael Agina <[email protected]> wrote: > > Dear All, > > I am implemnting new UC project at one customer location. > I installed the first node - publisher - succefully. > Now whenevr i add the 2nd node - subscriber - it tried to test connectivity > to first node but always fails and installion terminated. > There is network connectivity between the two nodes and from publisher i > can ping the new node - subscriber. > Also I reset the security password on the publisher [using Set *password*user > *security on CLI]* > > Any ideas as the connectivity test always fails ? > > -- > > Thanks and Best Regards, > Wael Agina > > > > _______________________________________________ > For more information regarding industry leading CCIE Lab training, please > visit www.ipexpert.com > > > > > > > -- > > Thanks and Best Regards, > Wael Agina > > > _______________________________________________ > For more information regarding industry leading CCIE Lab training, please > visit www.ipexpert.com > > > > > > > -- > > Thanks and Best Regards, > Wael Agina > > ------------------------------ > > * Disclaimer: This e-mail communication and any attachments may contain > confidential and privileged information and is for use by the designated > addressee(s) named above only. If you are not the intended addressee, you > are hereby notified that you have received this communication in error and > that any use or reproduction of this email or its contents is strictly > prohibited and may be unlawful. If you have received this communication in > error, please notify us immediately by replying to this message and deleting > it from your computer. Thank you. * > -- Thanks and Best Regards, Wael Agina
_______________________________________________ For more information regarding industry leading CCIE Lab training, please visit www.ipexpert.com