Hi Rafay,
Can you send the configuration from Site C? He was referring to the translation profile applied incoming on the voice-port on R3. It should look something like this: Voice-translation-rule 1 Rule 1 /^32143/ /3/ Or (I see two different called numbers below) Voice translation-rule 1 Rule 1 /^\+3432143/ /3/ Then create the profile and apply to voice-port Voice-translation-profile PSTN-IN Translate called 1 Voice-port 0/0/0:15 Translation-profile incoming PSTN-IN Jeff From: ccie_voice-boun...@onlinestudylist.com [mailto:ccie_voice-boun...@onlinestudylist.com] On Behalf Of Rafay Aslam Sent: Monday, November 29, 2010 1:22 PM To: Randall Crumm Cc: ccie_voice@onlinestudylist.com Subject: Re: [OSL | CCIE_Voice] Lab 4A Hi Attach is a complete PSNT Config. On Mon, Nov 29, 2010 at 3:12 PM, Randall Crumm <randall.cr...@flextronics.com> wrote: Can you send your voice translation rule/profile and how it is applied to the voice port? From: Rafay Aslam [mailto:rafayc...@gmail.com] Sent: Monday, November 29, 2010 12:11 PM To: Randall Crumm Cc: ccie_voice@onlinestudylist.com Subject: Re: [OSL | CCIE_Voice] Lab 4A Hi I have inital configuration loaded from PSTN router, here is debug from PSTN Router, I am calling from PSTN Phone to 3214-3005, so basically I want to see if my translation pattern works on BR2 Router whyic PSTN-WAN# Nov 29 20:07:25.135: ISDN Se0/1/0:23 Q931: Ux_DLRelInd: DL_REL_IND received from L2 Nov 29 20:07:28.499: ISDN Se0/0/1:23 Q931: Ux_DLRelInd: DL_REL_IND received from L2 Nov 29 20:07:30.063: ISDN Se0/0/0:23 Q931: Applying typeplan for sw-type 0xD is 0x0 0x0, Calling num 999 Nov 29 20:07:30.067: ISDN Se0/0/0:23 Q931: Sending SETUP callref = 0x0080 callID = 0x8001 switch = primary-ni interface = Network Nov 29 20:07:30.067: ISDN Se0/0/0:23 Q931: TX -> SETUP pd = 8 callref = 0x0080 Bearer Capability i = 0x8090A2 Standard = CCITT Transfer Capability = Speech Transfer Mode = Circuit Transfer Rate = 64 kbit/s Channel ID i = 0xA98381 Exclusive, Channel 1 Progress Ind i = 0x8583 - Origination address is non-ISDN Display i = 'Emergency Services' Calling Party Number i = 0x0080, '999' Plan:Unknown, Type:Unknown Called Party Number i = 0x80, '+3432143005' Plan:Unknown, Type:Unknown Nov 29 20:07:30.119: ISDN Se0/0/0:23 Q931: RX <- CALL_PROC pd = 8 callref = 0x8080 Channel ID i = 0xA98381 Exclusive, Channel 1 Nov 29 20:07:30.131: ISDN Se0/0/0:23 Q931: RX <- DISCONNECT pd = 8 callref = 0x8080 Cause i = 0x8081 - Unallocated/unassigned number Nov 29 20:07:30.135: ISDN Se0/0/0:23 Q931: TX -> RELEASE pd = 8 callref = 0x0080 Nov 29 20:07:30.143: ISDN Se0/0/0:23 Q931: RX <- RELEASE_COMP pd = 8 callref = 0x8080 Nov 29 20:07:30.155: ISDN Se0/0/0:23 Q931: Applying typeplan for sw-type 0xD is 0x0 0x0, Calling num 999 Nov 29 20:07:30.155: ISDN Se0/0/0:23 Q931: Sending SETUP callref = 0x0081 callID = 0x8002 switch = primary-ni interface = Network Nov 29 20:07:30.155: ISDN Se0/0/0:23 Q931: TX -> SETUP pd = 8 callref = 0x0081 Bearer Capability i = 0x8090A2 Standard = CCITT Transfer Capability = Speech Transfer Mode = Circuit Transfer Rate = 64 kbit/s Channel ID i = 0xA98381 Exclusive, Channel 1 Progress Ind i = 0x8583 - Origination address is non-ISDN Display i = 'Emergency Services' Calling Party Number i = 0x0080, '999' Plan:Unknown, Type:Unknown Called Party Number i = 0x80, '32143005' Plan:Unknown, Type:Unknown Nov 29 20:07:30.183: ISDN Se0/0/0:23 Q931: RX <- CALL_PROC pd = 8 callref = 0x8081 Channel ID i = 0xA98381 Exclusive, Channel 1 Nov 29 20:07:30.191: ISDN Se0/0/0:23 Q931: RX <- DISCONNECT pd = 8 callref = 0x8081 Cause i = 0x8081 - Unallocated/unassigned number Nov 29 20:07:30.195: ISDN Se0/0/0:23 Q931: TX -> RELEASE pd = 8 callref = 0x0081 Nov 29 20:07:30.203: ISDN Se0/0/0:23 Q931: RX <- RELEASE_COMP pd = 8 callref = 0x8081 Nov 29 20:07:34.139: ISDN Se0/1/0:23 Q931: Ux_DLRelInd: DL_REL_IND received from L2 Nov 29 20:07:37.499: ISDN Se0/0/1:23 Q931: Ux_DLRelInd: DL_REL_IND received from L2 On Mon, Nov 29, 2010 at 12:04 PM, Randall Crumm <randall.cr...@flextronics.com> wrote: HI, If you can call OB you still need to make sure your config for IB is correct. You need an IB dial peer and a translation rule to strip down the called number to 3001 HTH Randall From: ccie_voice-boun...@onlinestudylist.com [mailto:ccie_voice-boun...@onlinestudylist.com] On Behalf Of Rafay Aslam Sent: Monday, November 29, 2010 8:24 AM To: ccie_voice@onlinestudylist.com Subject: [OSL | CCIE_Voice] Lab 4A Hi I am doing Lab 4A, I can call from my BR2 Router to 999 or 911 which is PSTN Phone but from PSTN Phone I am unable to call my BR2 Phones ie 3214-3001 Regards Legal Disclaimer: The information contained in this message may be privileged and confidential. It is intended to be read only by the individual or entity to whom it is addressed or by their designee. If the reader of this message is not the intended recipient, you are on notice that any distribution of this message, in any form, is strictly prohibited. If you have received this message in error, please immediately notify the sender and delete or destroy any copy of this message
_______________________________________________ For more information regarding industry leading CCIE Lab training, please visit www.ipexpert.com