Hi all,
We have a native and holmium derivative in space group C2 (parameters
are 166 131 189 90 113 90) processed with XDS. When comparing the 2 data
sets in dataman or XSCALE, the coefficient correlation is 0.36.
So we reindexed one data set with -h k -l transformation, but this had
no effect (the data were exactly the same after reduction in the
asymetric unit).
Any suggestions to scale these 2 data sets ?
Thanks a lot,
Cheers,
Claudine
--
*************************************************************************