Claudine:

The transformation that you tried is identical to the crystal 2-fold, so
it didn't do anything.

Try a different re-indexing, such as h,k,l, to h,-k,-h-l.
I think CCP4's REINDEX program changes the cell parameters at the same
time.

-Dan


On Fri, 9 Jun 2006, claudine mayer wrote:

> ***  For details on how to be removed from this list visit the  ***
> ***          CCP4 home page http://www.ccp4.ac.uk         ***
>
>
> Hi all,
> We have a native and holmium derivative in space group C2 (parameters
> are 166 131 189 90 113 90) processed with XDS. When comparing the 2 data
> sets in dataman or XSCALE, the coefficient correlation is 0.36.
> So we reindexed one data set with -h k -l transformation, but this had
> no effect (the data were exactly the same after reduction in the
> asymetric unit).
>
> Any suggestions to scale these 2 data sets ?
>
> Thanks a lot,
>
> Cheers,
> Claudine
>
> --
> *************************************************************************