any opinions on how pseudo-centering, eg. C2 type in P2(1) etc
might affect results in shelxd,e...? i seem to have weak derivatives
with low res anom signal, and at low res many times distributions
are not random/could be mainly one CC for instance. 
but phasing produces nothing but gargabe. well perhaps because  a)
occopancies are too low b) with e.g. KI resolution is too low. (no anom
signal beyond 3.5Å+ice and so on) --but i am wondering if the
pseudo-symmetry has any effect?

thanks for tips/opinions,
tommi



-- 
Tommi Kajander, Ph.D.
Macromolecular X-ray Crystallography
Research Program in Structural Biology and Biophysics
Institute of Biotechnology
PO box 65 (Street address: Viikinkaari 1, 4th floor)
University of Helsinki
FIN-00014 Helsinki, Finland
Tel. +358-9-191 58903
Fax  +358-9-191 59940

Reply via email to