Hi Tim,

could you write a bit more about this cutoff. I've been using the 0 cutoff for 
the longest time as it seemed to be much more stringent to report.

Jürgen

-
Jürgen Bosch
Johns Hopkins Bloomberg School of Public Health
Department of Biochemistry & Molecular Biology
Johns Hopkins Malaria Research Institute
615 North Wolfe Street, W8708
Baltimore, MD 21205
Phone: +1-410-614-4742
Lab:      +1-410-614-4894
Fax:      +1-410-955-2926
http://web.mac.com/bosch_lab/<http://web.me.com/bosch_lab/>

On Feb 8, 2011, at 7:45 AM, Tim Gruene wrote:

Dear Simon,

I don't know how to change the output written to the log-file (maybe with the
TEST-card), but I wonder why you don't want to look at all of your data but only
those with I/sigI > 0? XDS reports all reflections with I/sigI > -3 for a good
reason.

Cheers, Tim

On Tue, Feb 08, 2011 at 12:17:35PM +0000, Simon Kolstoe wrote:
Dear ccp4bb,

I am quite a fan of XDS and have just upgraded to the latest version.

Normally, to assess the quality of my data, I look at the tables in
CORRECT.LP and especially the table "SUBSET OF INTENSITY DATA WITH
SIGNAL/NOISE >=  0.0 AS FUNCTION OF RESOLUTION".

However in my latest run I only get a single table for all the data
i.e. for signal/noise >= -3.0. Is there a command I can put in my
XDS.INP that will give me all the other tables or has the CORRECT.LP
logfile been altered in the most recent version of XDS?

(FYI my xds.inp obtained from the ESRF last week is copied below)

Thanks,

Simon



!=== File Automaticaly generated by mxCuBE
  !=== X-Ray data collected at: ESRF_ID14-1
  !=== Detector type: ADSC Quantum Q210
  !=== Date: Fri Feb 04 03:39:09 2011
  !=== User comments:

  JOB= ALL !XYCORR INIT COLSPOT IDXREF DEFPIX XPLAN INTEGRATE CORRECT
  !JOB= DEFPIX XPLAN INTEGRATE CORRECT

  DATA_RANGE= 1 190
  SPOT_RANGE= 1 20
  SPOT_RANGE= 1 4
  !SPOT_RANGE= 187 190
  BACKGROUND_RANGE= 1 4

  SECONDS=60
  MINIMUM_NUMBER_OF_PIXELS_IN_A_SPOT= 6
  STRONG_PIXEL= 6.0

  OSCILLATION_RANGE= 1.000
  STARTING_ANGLE= 0.000
  STARTING_FRAME= 1
  X-RAY_WAVELENGTH=  0.93340
  NAME_TEMPLATE_OF_DATA_FRAMES= ./data/sk1_1_???.img

  !STARTING_ANGLES_OF_SPINDLE_ROTATION= 0 180 10
  !TOTAL_SPINDLE_ROTATION_RANGES= 60 180 10

  DETECTOR_DISTANCE= 298.55
  DETECTOR= ADSC   MINIMUM_VALID_PIXEL_VALUE= 1   OVERLOAD= 65000
  ORGX= 1014.79    ORGY= 1029.10
  NX=  2048   NY=  2048   QX= 0.10200   QY= 0.10200
  VALUE_RANGE_FOR_TRUSTED_DETECTOR_PIXELS= 7000 30000

  DIRECTION_OF_DETECTOR_X-AXIS= 1.0 0.0 0.0
  DIRECTION_OF_DETECTOR_Y-AXIS= 0.0 1.0 0.0
  ROTATION_AXIS= 1.0 0.0 0.0
  INCIDENT_BEAM_DIRECTION= 0.0 0.0 1.0
  FRACTION_OF_POLARIZATION= 0.98
  POLARIZATION_PLANE_NORMAL= 0.0 1.0 0.0
  !== Default value recommended
  !AIR= 0.00026895

  SPACE_GROUP_NUMBER= 0
  UNIT_CELL_CONSTANTS= 0 0 0 0 0 0
  INCLUDE_RESOLUTION_RANGE= 50.0 2.4
  RESOLUTION_SHELLS= 15.0 8.0 4.0 3.0 2.8 2.6 2.5 2.4
  FRIEDEL'S_LAW= FALSE

  !FRIEDEL'S_LAW= TRUE
  TRUSTED_REGION= 0 1.40

  REFINE(INTEGRATE)= BEAM ORIENTATION CELL
  !== Default value recommended
  !DELPHI= 3.000
  MAXIMUM_NUMBER_OF_PROCESSORS= 16
  !MAXIMUM_NUMBER_OF_JOBS= 16

--
--
Tim Gruene
Institut fuer anorganische Chemie
Tammannstr. 4
D-37077 Goettingen

phone: +49 (0)551 39 22149

GPG Key ID = A46BEE1A


Reply via email to