Firstly, I think in Pymol there is no true electrostatic potential
calculator, but only a "charge-smoothed" surface presentation (
http://www.pymolwiki.org/index.php/Protein_contact_potential).

So, If you want to calculate the real electrostatic potential in Pymol (by
Possion-Boltzman method), you have to install a plugin such as APBS or
Delphi.

Personally, I prefer Delphi, because there is a good and simple tutorial
written by James Stroud from USC (
http://structure.usc.edu/howto/delphi-surface-pymol.html). And you also can
read the man page of Delphi where describe the details how it works (
http://wiki.c2b2.columbia.edu/honiglab_public/index.php/Software:DelPhi).

On Thu, May 26, 2011 at 12:51 PM, Tim Gruene <[email protected]>wrote:

> Dear Maher,
>
> as far as I know pymol uses the APBS (http://www.poissonboltzmann.org) for
> the
> calculations and your question is answered in the FAQ:
>
> http://www.poissonboltzmann.org/apbs/frequently-asked-questions/what-are-the-units-of-electrostatic-potential
> (kT/e)
>
> I don't know if this also answers your second question, but you could let
> us
> know in case it does.
>
> Tim
>
> On Wed, May 25, 2011 at 03:58:17PM -0700, Maher Alayyoubi wrote:
> > Hi everyone, I have two questions:
> >
> > 1- Does anybody know what are the units on the display ruler after you
> > calculate the vaccum electrostatics using pymol?
> >
> > 2- What are the default kT/e values used by pymol?
> >
> > Thank you,
> >
> >
> >
> >
> > Maher
>
> --
> --
> Tim Gruene
> Institut fuer anorganische Chemie
> Tammannstr. 4
> D-37077 Goettingen
>
> phone: +49 (0)551 39 22149
>
> GPG Key ID = A46BEE1A
>
>
> -----BEGIN PGP SIGNATURE-----
> Version: GnuPG v1.4.10 (GNU/Linux)
>
> iD8DBQFN3jDOUxlJ7aRr7hoRAuONAJ9/PlFL6WgLhiw44GrofkSibUw8IgCfRQxh
> YhReBu+gIxwpBm/7PHQwW4w=
> =dLaZ
> -----END PGP SIGNATURE-----
>
>


-- 
Xiaoguang Xue, PhD student
Utrecht University
Crystal & Structural Chemistry
Padualaan 8. Room N807
3584 CH Utrecht
The Netherlands
Tel. +31-30-253-2383