Dear Li(?),

 

The MolProbity server fixes the atom naming before the actual validation. You 
can use that. The ATOM/HETATM conversion is not needed, the PDB will do that 
for you when you deposit your structure model. If you really need it now, I 
guess it's easy enough to do with you favourite script language. 

 

Cheers,

Robbie

________________________________
> Date: Tue, 9 Aug 2011 16:48:23 +0900 
> From: [email protected] 
> Subject: [ccp4bb] **Possible spam**How to convert CNS PDB format to the 
> most current version of the PDB format? 
> To: [email protected] 
> 
> 
> Dear all, 
> 
> 
> 
> How to convert CNS pdb format to the most current version of the PDB format? 
> 
> 
> 
> e.g. "HN" (excluding N-term) in CNS output files should be changed to "H" 
> 
> 
> 
> And I don't know why the CNS put the N-terminal PCA in the ATOM 
> catagory. How to change it as HETATM? 
> 
> 
> 
> Thanks! 
> 
> 
> 
> College of Pharmacy 
> Pusan National University 
> Busan, Korea                                            

Reply via email to