Dear all, Thanks for all your reply and useful comment on this. Harry, You are right. I think there are individual mosaicity value corresponding to each image from scalepack. Clearly, we can get either average or range for report.
best, Hongshi On Fri, May 16, 2014 at 2:26 AM, Harry Powell <ha...@mrc-lmb.cam.ac.uk>wrote: > Hi > > I'm sure that a real HKL or Denzo/Scalepack expert will correct me, but my > recollection is that you don't use any of the values from Denzo, but the > value from Scalepack (see > http://www.hkl-xray.com/sites/default/files/HKL2000manual/chapter3/step14-1.htm, > for example). > > > On 16 May 2014, at 00:26, hongshi WANG wrote: > > Hello everyone, > > I am gonna report the mosaicity of my data set as required by the journal. > I processed the data using HKL2000. So I checked the denzo log file. I > found many different mosaicity values. The first one is default input > (0.3), the rest are corresponding to specific images. I think the mosaicity > value required should be an overall value or averaged value. Could you > please let me know how I can get it. Or some other software can determine > it. > I really appreciate your help and response! > > Hongshi > > > Harry > -- > ** note change of address ** > Dr Harry Powell, MRC Laboratory of Molecular Biology, Francis Crick > Avenue, Cambridge Biomedical Campus, Cambridge CB2 0QH > Chairman of European Crystallographic Association SIG9 (Crystallographic > Computing) > > > > > > > > > >