*Sorry Tim*...
The problem is *not limited to Cryo-EM* ....  It affects* all forms of
measurements*, including the measurement of *X-ray diffraction patterns*!
What is at stake here is that the* Nyquist-Shannon theorem* is
fundamentally *flawed *(Shannon 1949). In  *X Ray Crystallography* you
unfortunately lose the phases collecting such X Ray diffraction patterns,
but there is one good thing about that, namely: the *low frequency
diffraction peaks* disappear behind the central-beam stop!  The
discrete, *symmetric-sampling
approach* - for the sake of linearity - requires both the *low frequencies*
and the* high spatial frequencies* to be apodized to zero long before
reaching those limits of the sampling space. (After all, the
zero-order frequency of a deterministic *Continuous Fourier Transform*,
covers the whole universe in one direction and that is not a measurable
perspective on the physical world we live in!).

So sorry Tim,  you are not giving a valid argument for *ignoring the
Measurement Problem*!
But it is great to hear from you again, after so many years!

Cheers,
Marin


On Mon, Oct 6, 2025 at 10:46 AM Tim Gruene <[email protected]> wrote:

> I am so happy I do diffraction, not microscopy
> Tim
>
> On Sat, 4 Oct 2025 19:13:10 -0300
> Marin van Heel <[email protected]> wrote:
>
> > Dear All,
> >
> > Electron counting cameras in Cryo-EM have an unexpected direct
> > connection to the Measurement Problem in Quantum Mechanics. In fact,
> > the measurement problem already existed in Classical Newtonian
> > Physics due to its Deterministic Mathematical Axioms and is not
> > specifically tied to Quantum Mechanics. The Measurement Problem also
> > existed in Shannon’s sampling theorem. All measurements, and not only
> > those in Electron Microscopy must adhere to symmetric-sampling rules.
> > Check the link to a series of papers:
> >
> >
> https://www.linkedin.com/feed/update/urn:li:activity:7379515419424022528/
> >
> > Sorry, I know it is tough stuff…
> >
> > Marin
> >
> > ########################################################################
> >
> > To unsubscribe from the CCP4BB list, click the following link:
> > https://www.jiscmail.ac.uk/cgi-bin/WA-JISC.exe?SUBED1=CCP4BB&A=1
> >
> > This message was issued to members of www.jiscmail.ac.uk/CCP4BB, a
> > mailing list hosted by www.jiscmail.ac.uk, terms & conditions are
> > available at https://www.jiscmail.ac.uk/policyandsecurity/
>
>
>
> --
> --
> Tim Gruene
> Head of the Core Facility Crystal Structure Analysis
> Faculty of Chemistry
> University of Vienna
>
> Phone: +43-1-4277-70202
>
> https://ccsa.univie.ac.at
>
> GPG Key ID = A46BEE1A
>

########################################################################

To unsubscribe from the CCP4BB list, click the following link:
https://www.jiscmail.ac.uk/cgi-bin/WA-JISC.exe?SUBED1=CCP4BB&A=1

This message was issued to members of www.jiscmail.ac.uk/CCP4BB, a mailing list 
hosted by www.jiscmail.ac.uk, terms & conditions are available at 
https://www.jiscmail.ac.uk/policyandsecurity/

Reply via email to