Hi Tim Aaron Finke in Copenhagen ([email protected]) has a version of Aimless (“Lawless”) which he wrote to use wavelength-dependent scaling for Laue neutron data. That scaling is not appropriate for this case, but I have made a version of Pointless (1.16.2) which at least preserves a wavelength column from the input (actually it preserves any extra unrecognised columns in an unmerged MTZ input): this version will appear in a future CCP4 release. It would not be hard to make it add a wavelength column if requested.
Aimless could certainly copy such columns to the output unmerged flle, but the merged output has to have a single wavelength, presumably an average, which I think is the source of the PDB problem of discrepancy between unmerged and merged data Phil > On 11 Oct 2026, at 10:28, Tim Gruene > <[email protected]> wrote: > > CAUTION: This email originated from outside of the LMB: > [email protected]. > Do not click links or open attachments unless you recognize the sender and > know the content is safe. > If you think this is a phishing email, please forward it to > [email protected] > -- > > On Mon, 28 Sep 2026 17:00:33 +0200 > Sabine Schneider <[email protected]> wrote: > >> I combined data from two different crystals collected at two >> different beamlines, by scaling them together with aimless. However, >> the data were collected at slightly different wavelength: 0.968A and >> 0.976A and in the output file from aimless it states: 0.97192A. > Dear Sabine, > > not an answer to your question, but I still would correct the AI > agent's answer (and stimmulate a bug fix in aimless). In case you > combe data collected with different wavelength, and the file format > does not support flagging entries per wavelength so that you must > decide on reporting only one wavelength, you should always use the > shortest wavelength. The reason is simple crystallography: take a > crystal that diffracts beyond the limit lamba/2 (rare for MX, but > relevant for this question), you might end up with hkl-indices that > were impossible to measure. > > MTZ is quite flexible and I am sure one can include the wavelength per > reflection, which would circumvent the problem (and better the PDB > adjusts to good practice than the community adjusts to poor > implementations). > > Best, > Tim > > -- > Tim Gruene > Head of the CF Crystal Structure Analysis > Faculty of Chemistry > University of Vienna > > Phone: +43-1-4277-70202 > > GPG Key ID = A46BEE1A > > ######################################################################## > > To unsubscribe from the CCP4BB list, click the following link: > https://www.jiscmail.ac.uk/cgi-bin/WA-JISC.exe?SUBED1=CCP4BB&A=1 > > This message was issued to members of www.jiscmail.ac.uk/CCP4BB, a mailing > list hosted by www.jiscmail.ac.uk, terms & conditions are available at > https://www.jiscmail.ac.uk/policyandsecurity/ > ######################################################################## To unsubscribe from the CCP4BB list, click the following link: https://www.jiscmail.ac.uk/cgi-bin/WA-JISC.exe?SUBED1=CCP4BB&A=1 This message was issued to members of www.jiscmail.ac.uk/CCP4BB, a mailing list hosted by www.jiscmail.ac.uk, terms & conditions are available at https://www.jiscmail.ac.uk/policyandsecurity/