> On Jan 1, 2022, at 2:21 PM, Grant Taylor via cctalk <cctalk@classiccmp.org> 
> wrote:
> 
> On 1/1/22 12:17 PM, Dennis Boone via cctalk wrote:
>> IIRC nothing in the VAX cpu actually requires 3 phase.  The PDU(s) just eat 
>> that from the wall.
> 
> I think that's the same with all the /computer/ equipment that I've seen 
> which connects to 3ɸ power.  A single phase could be used for all of it.  But 
> I'm told that it's simpler / more economical (from a wiring / cable plant 
> point of view) to deliver more power to the equipment as 3ɸ than it is 1ɸ.

Largely true, but some disk drives (RP06?  RP04?) use 3-phase spindle motors.  
And mainframes may use 3-phase power supplies; CDC 6000 mainframes do, though 
with those it's 3 phase 400 Hz produced by motor-generators (which in turn run 
off 3-phase mains power).

        paul