Dear Christiane

A few comments to several of your separate aerocom emails:

cell_height: Is that in m? Does it mean cell_thickness i.e. vertical extent,
which has already been proposed?

potential_temperature_difference_between_700hPa_and_1000hPa: I would suggest
difference_in_air_potential_temperature, with difference_in_X being a new
transformation, and a coordinate variable of air_pressure whose bounds
indicate 700 and 1000 hPa.

due_to_net_production_and_emission_from_biomass_burning: Could that just be
due_to_biomass_burning?

atmosphere_number_concentration_of_X_in_air: I think "atmosphere_" is not
necessary; this is a "local" property.

Best wishes