Dear Christiane A few comments to several of your separate aerocom emails:
cell_height: Is that in m? Does it mean cell_thickness i.e. vertical extent, which has already been proposed? potential_temperature_difference_between_700hPa_and_1000hPa: I would suggest difference_in_air_potential_temperature, with difference_in_X being a new transformation, and a coordinate variable of air_pressure whose bounds indicate 700 and 1000 hPa. due_to_net_production_and_emission_from_biomass_burning: Could that just be due_to_biomass_burning? atmosphere_number_concentration_of_X_in_air: I think "atmosphere_" is not necessary; this is a "local" property. Best wishes Jonathan _______________________________________________ CF-metadata mailing list [email protected] http://mailman.cgd.ucar.edu/mailman/listinfo/cf-metadata