Yes, there are. I forget the appropriate standard but your supposed to use individually shielded pairs. HOWEVER, this doesen't become a problem unless your going a really long distance such as 500-1000 feet. The teleco themselves run T1's on 100 pairs that are used as IDFs inside of high rises all the time without trouble.
One thing I have found that can cause errors like this is clocking. Traditionally, point to point spans would require one side set to master clock, the other side set to slave clock. But these days telco's run T1's through multiplexers and while they are not supposed to put clock on to the span, many many times I will have to set both sides to obtain clock from the network. Ted > -----Original Message----- > From: [EMAIL PROTECTED] > [mailto:[EMAIL PROTECTED] Behalf Of Vincent Aniello > Sent: Friday, May 18, 2007 8:25 AM > To: [email protected] > Subject: [c-nsp] T1 Cables > > > Are there cables specifically for use with T1s that we should be using > to connect circuits to our Cisco routers with integrated CSU/DSUs? We > currently use CAT5E cables and have chronic problems with errors on a > few of our circuits. The cable length between the smart jack and router > is 25 feet. > > > > Thanks. > > > > V/ > > > > > > > > Disclaimer: Any references to Pipeline performance contained > herein are based on historic performance levels which Pipeline > expects to maintain or exceed but nevertheless does not > guarantee. Congested networks, price volatility, or other > extraordinary events may impede future trading activities and > degrade performance statistics. > _______________________________________________ > cisco-nsp mailing list [email protected] > https://puck.nether.net/mailman/listinfo/cisco-nsp > archive at http://puck.nether.net/pipermail/cisco-nsp/ > _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/