The "stops routing" sounds like FIB issues causing CEF to turn off on the linecards. How much memory do you have on the linecards? ( "show diags | inc (SLOT|MEM-|Engine)" ). If you have less than 256M processor memory on any linecard you may want to look into taking it up to 256M.
To check if this is indeed happening, the next time it happens try executing a "execute-on slot <slot> show cef state", if CEF is disabled, the LC may have run out of memory. ~Matt -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Mark Tinka Sent: Friday, August 10, 2007 11:45 AM To: [email protected] Subject: Re: [c-nsp] Quick question about redundant connections. On Friday 10 August 2007 22:47, Drew Weaver wrote: > Is there a particular scheme for downstream switches to verify that an > upstream router is actually functioning "properly" on a periodic > basis? Sounds like a probable candidate for BFD; but doesn't quite explain why your box "stops routing". BFD: http://cisco.com/en/US/products/ps6017/products_feature_guide09186a00803 fbe87.html Mark. _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/