Hi all, we've run into weird problems with recent XENPAKs on Cat6509 platform running 12.2(18)SXF10. These are:
- XENPAK is not recognized when plugged into shutdown port. However, after "no shut" XENPAK comes online and passes traffic fine - it is not possible to turn off the laser ouput. Configuring "shutdown" disables the laser just for 2 seconds, then it comes back on. Searching through the Cisco docs indeed confirms that for LR+, ER+ and DWDM XENPAKs produced in 2007 a SMU is required on CRS-1 platform: http://www.cisco.com/web/Cisco_IOS_XR_Software/pdf/xenpak_smu.pdf However, no matching doc can be found for cat6500, or cisco7600. We've also tested with 12.2(33)SXH - the problem is resolved. Does anyone have an open case and/or bug ID for this issue? Would the fix also appear in the next -SXF rebuild ? Thanks & kind regards, -------------------------------------------------------------------------- ---- ---- ---- Marian Ďurkovič network manager ---- ---- ---- ---- Slovak Technical University Tel: +421 2 524 51 301 ---- ---- Computer Centre, Nám. Slobody 17 Fax: +421 2 524 94 351 ---- ---- 812 43 Bratislava, Slovak Republic E-mail/sip: [EMAIL PROTECTED] ---- ---- ---- -------------------------------------------------------------------------- _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/