Does this happen with both modular and non-modular SXH images ? Not capable of running BFD on SVIs after having issues with BFD on ZU2 makes me a very unhappy customer.
Rubens On 10/18/07, Justin Shore <[EMAIL PROTECTED]> wrote: > During a recent upgrade from the ZU2 code to SXH on one of our 6524s I > ran into BFD trouble. In ZU2 we had BFD configured on a pair of SVIs > and it worked great. Apparently in SXH BFD is only supported on > physical interfaces. > > TAC told me some time back that ZU2 was a special SX release to support > the ME6524s. Does anyone know why the feature regression occured or > even better if this will be fixed in a later release? L3 interfaces > aren't possible in our setup without some serious reworking. > > Thanks > Justin > > _______________________________________________ > cisco-nsp mailing list [email protected] > https://puck.nether.net/mailman/listinfo/cisco-nsp > archive at http://puck.nether.net/pipermail/cisco-nsp/ > _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/