You should try clock s internal first if you have SDH gear in the middle.

Aaron

On Dec 12, 2007 9:17 AM, Ziad Majzoub <[EMAIL PROTECTED]> wrote:

> Niels, are you suggesting clock source internal , on both ends ?
> BTW there is definitely some SDH equipment on the path
> regards
>
>
>
> On Dec 12, 2007 7:38 AM, Niels Bakker <[EMAIL PROTECTED]> wrote:
>
> > * [EMAIL PROTECTED] (Ziad Majzoub) [Tue 11 Dec 2007, 04:07 CET]:
> > >I'm seeing underruns errors on local STM1 interface,
> > >on the remote router i'm seeing runts, aborts and imput errors
> > >the controller is clean(during a certain period).
> >
> > Try switching both to line clock source if there is SDH equipment
> > inbetween (your use of 'remote' implies that).
> >
> >
> >        -- Niels.
> >
> > --
> > _______________________________________________
> > cisco-nsp mailing list  [email protected]
> > https://puck.nether.net/mailman/listinfo/cisco-nsp
> > archive at http://puck.nether.net/pipermail/cisco-nsp/
> >
> _______________________________________________
> cisco-nsp mailing list  [email protected]
> https://puck.nether.net/mailman/listinfo/cisco-nsp
> archive at http://puck.nether.net/pipermail/cisco-nsp/
>
_______________________________________________
cisco-nsp mailing list  [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/

Reply via email to