Hi Steve... Traditionally (if possible) you would have separate management VLAN's to each site for management purposes. The intermediary is most likely not permitting VLAN1 and/or untagged traffic (quite common).
Hope this helps... Paul -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Steve Bertrand Sent: Tuesday, July 22, 2008 4:42 PM To: [email protected] Subject: [c-nsp] Native and management VLAN confusion Hi everyone, We have a scenario regarding VLANs in which I'm confused as to how to access the remote switches: COE 2924 XL native vlan 1 | | trunk | vlans 500, 501, 502 | | intermediary network 5500 / | \ / | \ trunk trunk trunk / | \ CPE CPE2 CPE3 2924 XL 2924XL 2924XL vlan 500 vlan 501 vlan 502 Untagged traffic does not pass from CPE to COE through the intermediary. I'm confused as to how I need to configure things VLAN-wise in order to be able to remotely manage the CPE switches from the CO, through the independent intermediary. The native and management VLAN is 1 on the CPE side. Could someone point me in the direction on the most appropriate way to make the CPE gear reachable? Thanks, Steve _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/ _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/