Darryl Dunkin wrote:
The line code for individual T1s is handled on the MUX. Based on the
counters of line code violations, I'd check there first and see what it
is set to.

Thanks to all the replies.  Here what the mux is configured for currently:

- DS3
    ds3    circuitid "DS3"
    ds3        clock int
    ds3  clockrevert on
    ds3    equipment off
    ds3      framing m23
    ds3       length short
    ds3         line off
    ds3   loopdetect off
    ds3      payload off
    ds3         send off
    ds3    threshold off
    Performance Thresholds:         15 min.      1 hour       1 day
                                   --------    --------    --------
    coding violations - line:           387        1161        3865
    errored seconds - line:              25          75         250
    coding viols-path p-bit:            382        1146        3820
    err seconds - path p-bit:            25          75         250
    loss of signal secs - line:           4          12          40
    sev err seconds - line:               4          12          40
    sev err sec - path cp-bit:            4          12          40

-  1
    ds1 1   circuitid "DS1 1"
    ds1 1      enable
    ds1 1   equipment off
    ds1 1      length dsx0
    ds1 1        line off
    ds1 1    linecode b8zs
    ds1 1  loopdetect off
    ds1 1    metallic off
    ds1 1        send off
    Performance Thresholds:         15 min.      1 hour       1 day
                                   --------    --------    --------
    coding violations - line:         13340       40020      133400
    errored seconds - line:              65         195         648

-  2
    ds1 2   circuitid "DS1 2"
    ds1 2      enable
    ds1 2   equipment off
    ds1 2      length dsx0
    ds1 2        line off
    ds1 2    linecode b8zs
    ds1 2  loopdetect off
    ds1 2    metallic off
    ds1 2        send off
    Performance Thresholds:         15 min.      1 hour       1 day
                                   --------    --------    --------
    coding violations - line:         13340       40020      133400
    errored seconds - line:              65         195         648


So it looks like my DS1 linecode is ok. The length of "dsx0" corresponds to 0-110'. Would clocking keep the DS1 from coming up? I'm currently trying to generate the clock on the 7206 since we don't have another external clock source in that CO. Eventually we'll have several M13s (though probably not another Wide Bank brand... what a clunky EOF...). Should I generate the clock on the M13 or the router?

Thanks
 Justin