On 2008-12-19 06:32, Tony wrote:

If I FTP a file from PC2 to PC1 I get speeds of 97Mbps (near enough
to wire speed of 100Mbps). Nice. I then change the config so that the
interfaces are in a VRF, like this: Testing using the FTP transfer
again I get an average transfer speed of around 14Mbps (not so
nice).

My wild guess would be to check for extended-match in sdm template:

http://www.cisco.com/en/US/docs/switches/lan/catalyst3550/software/release/12.2_25_seb/configuration/guide/swiprout.html#wp1213867

Change that, reboot the switch and then do again the tests for
interfaces in VRF. As for the other tests with routing over SVIs -
very strange :) as 3550 is routing in hardware.

--
"Don't expect me to cry for all the     |               Łukasz Bromirski
 reasons you had to die" -- Kurt Cobain |    http://lukasz.bromirski.net
_______________________________________________
cisco-nsp mailing list  [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/