On 2008-12-19 06:32, Tony wrote:
If I FTP a file from PC2 to PC1 I get speeds of 97Mbps (near enough to wire speed of 100Mbps). Nice. I then change the config so that the interfaces are in a VRF, like this: Testing using the FTP transfer again I get an average transfer speed of around 14Mbps (not so nice).
My wild guess would be to check for extended-match in sdm template: http://www.cisco.com/en/US/docs/switches/lan/catalyst3550/software/release/12.2_25_seb/configuration/guide/swiprout.html#wp1213867 Change that, reboot the switch and then do again the tests for interfaces in VRF. As for the other tests with routing over SVIs - very strange :) as 3550 is routing in hardware. -- "Don't expect me to cry for all the | Łukasz Bromirski reasons you had to die" -- Kurt Cobain | http://lukasz.bromirski.net _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/