Do a snmpwalk on 1.3.6.1.4.1.9.9.13.1.3.1, this gives info on all the temp sensors in the box.
Martin On Wednesday, 15 April, 2009 07:10 Engelhard Labiro <> wrote: > Couldn`t find doco on cisco that state it has a temp.sensor..but > "sh env" of the module indicates that the chassis is able to show the > temp. of the card. > > sh module > Mod Ports Card Type Mode > --- ----- -------------------------------------- ------------------ > 1 8 CEF720 8 port 10GE with DFC WS-X6708-10GE > 2 8 CEF720 8 port 10GE with DFC WS-X6708-10GE > 3 48 CEF720 48 port 1000mb SFP WS-X6748-SFP > 4 48 CEF720 48 port 10/100/1000mb Ethernet WS-X6748-GE-TX > 5 2 Supervisor Engine 720 (Active) WS-SUP720-3B > > xxxxx>sh environment temperature module 3 > module 3 outlet temperature: 50C > module 3 inlet temperature: 36C > module 3 device-1 temperature: 36C > module 3 device-2 temperature: 46C > > 2009/4/15 Hiromasa Sekiguchi <hiromasa.sekigu...@ctc-g.co.jp>: >> Hi all, >> >> Does WS-X6748-SFP have temperature sensor? >> >> Can we confirm it on cisco web site? >> >> Regards, >> Hiromasa >> >> _______________________________________________ >> cisco-nsp mailing list cisco-...@puck.nether.net >> https://puck.nether.net/mailman/listinfo/cisco-nsp >> archive at http://puck.nether.net/pipermail/cisco-nsp/ >> > _______________________________________________ > cisco-nsp mailing list cisco-nsp@puck.nether.net > https://puck.nether.net/mailman/listinfo/cisco-nsp > archive at http://puck.nether.net/pipermail/cisco-nsp/ _______________________________________________ cisco-nsp mailing list cisco-nsp@puck.nether.net https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/