On Tue, Sep 08, 2009 at 04:21:03PM +0200, Peter Rathlev wrote: > AFAIK there's no way around it. And AFAIK it's not Sup720 specific.
One thing that might be 7600/6500 specific on this matter is that we have been seeing multiple crashes on both primary and secondary supervisors when changing elements such as this on this platform running 12.2SR/12.2SX code. We've figured the safest way is to configure this in parallel, then try and clean up every line of VRF configuration relating to the old VRF. We've seen crashes where there's memory corruption and the primary supervisor crashes. Or where the line-by-line sync to the secondary in SSO causes it to crash. Both are triggered by trying to remove the VRF RD and reconfigure it. TAC haven't been able to reproduce either, so unfortunately we've got no bug ID. Cheers, Rob -- Rob Shakir <[email protected]> Network Development Engineer GX Networks/Vialtus Solutions ddi: +44208 587 6077 mob: +44797 155 4098 pgp: 0xc07e6deb nic-hdl: RJS-RIPE This email is subject to: http//www.vialtus.com/disclaimer.html _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/