Yup, that's right. Each module applies QoS independently. :(


Sharlon Carty
ICT Technician
 
P.O. Box 1110
Soualiga Boulevard #5
Pond Island, Philipsburg,
St. Maarten, Netherlands Antilles 
 
 



Mobile:   +599 527-4002

E-mail:     [email protected] 
                  http://www.telemgroup.an/  
--------------------------------------------------------------------------
DISCLAIMER - The information contained in this e-mail and any attachment(s) is 
(are) privileged and/or confidential and solely intended for the use of the 
addressee(s). If you have received this e-mail unintentionally, please inform 
the TelEm Group immediately and delete this communication and any attachment(s) 
without copying. Any unauthorized use or dissemination of this e-mail in whole 
or in part is strictly prohibited. The TelEm Group does not guarantee that this 
e-mail is secure or error-free as information could be intercepted, corrupted, 
lost, destroyed, delayed or incomplete, or may contain viruses
TelEm Group therefore does not accept liability for any damages or errors or 
omissions in the contents of this message and which arise as a result of this 
e-mail.
 
-----Original Message-----
 

From: [email protected] 
[mailto:[email protected]] On Behalf Of Kevin Loch
Sent: Wednesday, March 03, 2010 6:57 PM
To: [email protected]
Subject: Re: [c-nsp] 7606 RSP720

Sharlon Carty wrote:
> Hello,
> 
>  
> 
> I have a police-map applied to a vlan interface set to 10mbit. Works fine, as 
> long as traffic is routed on the CEF720 48 port module. But the moment 
> traffic is routed on the RSP720, traffic is above the 10mbit. 
> 
> Is there something on the RSP720 that needs to enabled?  
> 

The SIP-600 includes a DFC.  Unfortunately on this platform each
forwarding engine makes policing decisions independently. In
addition all policing decisions are made on the ingress forwarding
engine, even for egress policers.

Ingress traffic on the SIP-600 may be rate limited to 10mbps, but you
could get another 10mbps of ingress traffic from line cards that use the
PFC on the rsp720.  If you have other DFC's in the system they would
also add to the total if there is ingress traffic for that vlan on them.

- Kevin
_______________________________________________
cisco-nsp mailing list  [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/
 

_______________________________________________
cisco-nsp mailing list  [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/

Reply via email to