I am going to take a guess in that he will not be using fibre from a service provider.
He states that the issue is on a fibre link between a core switch and this 3560... On 24 Jan 2011, at 08:09, Muhammad Jawwad Paracha wrote: > Hi Farooq > > I have gone through similar problem with one of our customer in recent days. > This issue is related to fiber service provider, get OTDR report from > service provider also attach "show interface tengig0/x trans detail" output > from both device. > > Regards > > Jawwad Paracha > > IBM > > On Mon, Jan 24, 2011 at 12:41 PM, Farooq Razzaque > <[email protected]>wrote: > >> >> Hi All >> >> I am receiving the following errors on aggregation switch >> (WS-C3560E-12SD-E) which is connected with Core switch (Cat. 6513) >> >> %SFF8472-5-THRESHOLD_VIOLATION: Te0/2: Rx power low warning; Operating >> value: -12.5 dBm, Threshold value -9.9 dBm >> >> >> >> >> >> >> >> _______________________________________________ >> cisco-nsp mailing list [email protected] >> https://puck.nether.net/mailman/listinfo/cisco-nsp >> archive at http://puck.nether.net/pipermail/cisco-nsp/ >> > _______________________________________________ > cisco-nsp mailing list [email protected] > https://puck.nether.net/mailman/listinfo/cisco-nsp > archive at http://puck.nether.net/pipermail/cisco-nsp/ _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/